Datasheet

Read the in-depth technical information.

Pager

The Visit Pager
Art. no. BE1470 

Technical information

Power supply

Mains power:

Via Visit Charger, BE1260 

Battery power:

1 x 1.5 V AAA alkaline or 
1.2 V AAA NiMh rechargeable battery.

Operating time:

Alkaline: 2 – 3 weeks
NiMh: Approximately 1 week on one charge

Power consumption:

Active: 220 mA
Idle position: 1 mA

Radio function

Radio frequency:

868,3MHz

Number of Radio Keys: 

64 Radio Keys as standard. Special software can be used to increase these to 256 Radio Keys in increments of 64 per software purchase. Contact the nearest supplier for further information.

Coverage:

The normal coverage between a transmitter and receiver in the Bellman Visit 868 System is approximately 200 metres with a clear line of sight. Coverage is reduced if walls and large objects screen off the signals. Any thick walls constructed of reinforced concrete will greatly affect coverage. The system may also be affected by radio transmitters such as TV transmitters, computers, mobile phones, etc. This means that a unit may work perfectly in one part of the room but not at all in another.

Activation

Radio:

Bellman Visit 868 system.

Via analogue telephone network: 

26 - 120 V RMS, 15 - 100 Hz.

Output signals

Vibrator power:

Built-in

Additional information

For indoor use only

Dimensions W x H x D:

57 x 86 x 29 mm

Weight:

With battery: 70 g
Without battery: 55 g

Colour:

Grey with red function button.

Accessories

Bellman Visit Charger BE1260
Bellman Bed Vibrator BE1270 (connected to BE1260)

RESOURCES
MANUAL
APPENDIX (EN)